Features:
• Pure sine wave output
• Max 140A automatic 3-stage battery charger
• Charger current is Adjustable (0-100%)
• Automatically send signal to start generator
• Supporting USB communication and BTS & AGS port
• Battery/AC priority

Specification:
| MODEL | EP30-8KW PRO | EP30-10KW PRO | EP30-12KW PRO |
|---|---|---|---|
| Nominal Battery System Voltage | 48VDC | 48VDC | 48VDC |
| INVERTER OUTPUT | |||
| Continuous output power | 8.0KW | 10.0KW | 12.0KW |
| Surge rating | 24000VA | 30000VA | 36000VA |
| Capable Of Starting Electric Motor | 4HP | 5HP | 6HP |
| Output waveform | Pure sine wave / same as input (bypass mode) | ||
| Inverter Efficiency(Peak) | >88% | ||
| Line mode efficiency | >95% | ||
| Power factor | 1.0 | ||
| Nominal output voltage RMS | 220V / 230V / 240VAC ±10% (RMS) | ||
| Output frequency | 50Hz | ||
| Short circuit protection | Yes (1sec after fault) | ||
| Typical transfer time | 10ms(max) | ||
| AC INPUT | |||
| Voltage | 90-280VAC | ||
| Selectable Voltage Range | 170-280VAC(For Personal Computers) | ||
| Frequency Range | 50Hz / 60Hz | ||
| BATTERY | |||
| Minimum start voltage | 40.0V±0.6 / 42.0V±0.6 | ||
| Low battery alarm | 42-50VDC | ||
| Low battery Cutoff | 40.0V±0.6 / 42.0V±0.6 | ||
| High voltage alarm | 60VDC | ||
| High battery voltage recover | 57VDC | ||
| Idle consumption-search mode | <60W when power saver on | ||
| CHARGER | |||
| Output voltage | Depends on battery type | ||
| Charger AC input breaker rating | 80A | ||
| Max charge power rate | 1/3 Rating power | ||
| Overcharge protection S.D. | 62.8VDC | ||
| Maximum Charge Current | 100A | 120A | 140A |
| BTS | |||
| Temperature rate @25°C | 4mv charging voltage descent, per 1℃ rise | ||
| BYPASS & PROTECTION | |||
| Input voltage waveform | Sine wave (grid or generator) | ||
| Nominal voltage | 220V / 230V / 240VAC | ||
| Max input AC voltage | 300VAC for 230VAC HV mode | ||
| Nominal input frequency | 50Hz or 60Hz | ||
| Overload protection (SMPS load) | Circuit breaker | ||
| Output short circuit protection | Circuit breaker | ||
| Bypass breaker rating | 63A | ||
| Max bypass current | 63Amp | ||
| MECHANICAL SPECIFICATIONS | |||
| Mounting | Wall mount | ||
| Inverter dimensions (W*H*D) (mm) | 670*410*215 | ||
| Inverter weight (solar chg) (kg) | 67.5 | 74 | 74 |
| Shipping dimensions (W*H*D) (mm) | 802*533*429.5 | ||
| Shipping weight (solar chg) (kg) | 87 | 93.5 | 93.5 |
| OTHER | |||
| Operation Temperature Range | 0℃ to 40℃ | ||
| Storage Temperature | -15℃ to 60℃ | ||
| Audible Noise | 60bB MAX | ||
| Display | LED+LCD | ||